Climatic Testing
We have more than 20 chambers that have the ability to simulate most climatic
conditions. These chambers cover the extremes of temperature, altitude,
humidity, temperature cycling, solar heating and corrosive atmospheres. All
chambers are continuously monitored by our central SCADA computer-controlled
data collection system.
Key features: - Temperature, altitude and humidity facilities
- Thermal vibration facilities
- Thermal vacuum chamber for space simulation testing
- Management of various types of test programmes - e.g. Reliability Growth
Programmes (RGP), Reliability Development testing (RDT), Environmental Stress
Screen (ESS), Highly Accelerated Life Testing (HALT)
- Flexible service 12 hours a day, seven days a week.
We provide assistance with interpretation of specifications and design of
appropriate test programmes. We can also design and build special-to-type test
facilities to undertake some of the more unusual or more intense types of
testing. Summary of Tests Capabilities and Facilities Environmental
Engineering - Climatic Test | Temperature: | Minimum:
-100°C - Maximum 500°C (constant and cycling) | | Humidity: | 10% to
98% | | Altitude: | to 100,000ft
(Rapid and Slow rates of change) | | Pressure: | 1.7bar
(-15,000ft) | | Water: | Drip, Spray
and immersion | | Salt
Fog: | Steady state
and cyclic tests | | Direct
injection Ln2 Temperature Chambers: | 4 (Ramp rate
up to 30°C per minute) | | Indirect
injection Ln2 Temperature Chambers: | 4 (Up to
4m³) | | Mechanical
Temperature Chambers: | 7 | | Humidity
Chambers: | 1 | | Temperature-altitude-humidity
Chambers: | 2 | | Salt Fog
Chamber: | 1 | | Thermal Vacuum
Chamber: | 1 | | Pressure/Vacuum
Chamber: | 1 | | Other
Tests | Frost, Icing,
Water, Immersion, Solar Radiation,
Fluid Contamination | Multiple
channel data logging of many types of signal is also available.
|
|